Solar & Wind Distribution Equipment

From the string combiner box to the connection bay — plus the kiosk substation and distribution transformer range behind it. All supplied to Australian conditions and standards.

Product range at a glance

Comparison of Omnetric solar, wind, transformer and substation products by category and typical application
ProductCategoryBest suited to
Inverter Duty TransformersSolar & Wind PlantUtility-scale solar farms and BESS where inverter blocks feed a medium-voltage collection network.
Grid Connection TransformersSolar & Wind PlantSolar and wind farms connecting at transmission level, where impedance, tap range and fault strength are set by the connection agreement.
Central InvertersPower ConversionUtility-scale solar farms built around repeatable inverter blocks.
String InvertersPower ConversionCommercial and industrial rooftops and small ground-mount plants where a central inverter is oversized.
HV & LV SwitchgearSwitchgear & ProtectionPlant substations, switchyards and the handover bay where power is transferred to the network operator.
Cabling & String Combiner BoxesCabling & ConnectionProjects at the cable scheduling stage, where consolidated supply avoids offcuts and mismatched drum lengths.
Earthing & Lightning ProtectionEarthing & ProtectionSolar and wind sites where the earthing grid is laid in alongside cable trenching.
SCADA, OFC & MeteringControl & MonitoringPlants that must report faults to a control room and curtail output on network instruction.
Kiosk SubstationsPackaged SolutionsBrownfield sites, commercial subdivisions and remote operations where on-site civil works must be minimised.
Fin Wall TransformersDistribution TransformersUtility and industrial distribution networks where lifetime maintenance cost is the deciding factor.
Dry Type TransformersDistribution TransformersIndoor substations, high-rise buildings, data centres and sensitive commercial environments.
FM Fire Mitigation TransformersFire-Rated SolutionsDense urban developments and constrained sites where every square metre carries cost.
Standard Substation TransformersDistribution TransformersHeavy industrial plants and mining operations needing proven, robust, compliant units.

Solar & Wind Plant

Inverter Duty Transformers

Step-up transformers that lift inverter output to collection voltage — typically 33 kV — specified for the harmonics and daily cycling of inverter-fed generation.

  • Sized around inverter blocks, commonly in the 3–4 MVA class
  • Specified for harmonic content and the thermal cycling inverter output imposes
  • Station service and isolation units supplied alongside for auxiliary and standby supply

Best for: Utility-scale solar farms and BESS where inverter blocks feed a medium-voltage collection network.

Key specifications

Typical secondary
33 kV collection, or to project spec
Duty
Inverter-fed, cyclic loading
Standards
AS 60076 and IEC equivalents

Solar & Wind Plant

Grid Connection Transformers

Power transformers that take plant collection voltage up to transmission level for connection to the NEM.

  • Sourced across the 132 kV, 220/275 kV and 330 kV connection range
  • ONAF and OFAF cooling options for sites where ambient exceeds 40–45 °C
  • On-load tap changers for voltage regulation under variable renewable output

Best for: Solar and wind farms connecting at transmission level, where impedance, tap range and fault strength are set by the connection agreement.

Key specifications

Connection voltage
132 kV to 330 kV, per NSP requirement
Cooling
ONAN, ONAF or OFAF to suit site ambient
Regulation
On-load tap changer

Power Conversion

Central Inverters

Block-scale DC to AC conversion for utility projects, typically supplied in the 3–4 MVA range per unit.

  • Matched to the inverter duty transformer and collection design
  • Block architecture that keeps DC cable runs — and DC losses — short
  • Supplied with the monitoring interfaces the plant SCADA expects

Best for: Utility-scale solar farms built around repeatable inverter blocks.

Key specifications

Typical unit size
3–4 MVA
Function
DC to AC conversion at block level
Integration
Paired with inverter duty transformers

Power Conversion

String Inverters

Distributed DC to AC conversion for smaller plants and rooftop systems, from a few hundred kilowatts to a couple of megawatts.

  • Suited to plants around 500 kW to 2 MW, and to commercial rooftop systems
  • Distributed architecture that limits the impact of any single unit fault
  • Simpler civil and installation scope than a central inverter block

Best for: Commercial and industrial rooftops and small ground-mount plants where a central inverter is oversized.

Key specifications

Typical plant size
500 kW to 2 MW
Function
DC to AC conversion at string level
Application
Small utility, commercial and rooftop

Switchgear & Protection

HV & LV Switchgear

High and low tension switchgear for plant collection systems, substations and the connection bay.

  • HT switchgear for collection and substation duty
  • LT switchgear and distribution boards for auxiliary and site supply
  • Isolators, protection and instrument equipment for the connection bay

Best for: Plant substations, switchyards and the handover bay where power is transferred to the network operator.

Key specifications

Range
HT and LT
Application
Collection, substation and bay
Testing
To network operator safety requirements

Cabling & Connection

Cabling & String Combiner Boxes

DC, AC, HT and control cable supplied to the plant cable schedule, with string combiner boxes for the DC side.

  • DC string, AC collection, HT and control cable to one schedule
  • Sizing set by run length, so losses stay inside the design allowance
  • String combiner boxes consolidating array output ahead of the inverter

Best for: Projects at the cable scheduling stage, where consolidated supply avoids offcuts and mismatched drum lengths.

Key specifications

Cable types
DC, AC, HT and control
Sizing basis
Run length and loss allowance
Supply basis
Against the project cable schedule

Earthing & Protection

Earthing & Lightning Protection

Earthing and surge protection materials for array, substation and switchyard earthing grids.

  • Earth strip, earthing rods and grid materials
  • Lightning arresters for array, substation and bay protection
  • Supplied to suit the earthing design and soil resistivity results

Best for: Solar and wind sites where the earthing grid is laid in alongside cable trenching.

Key specifications

Materials
Earth strip, rods and grid hardware
Surge protection
Lightning arresters
Stage
Installed with trenching and cabling

Control & Monitoring

SCADA, OFC & Metering

Remote monitoring and control equipment, fibre communications and revenue metering for the main control room and the bay.

  • SCADA for remote monitoring and generation curtailment when the network requires it
  • Optical fibre cable linking inverters, substation and the main control room
  • Control room equipment with battery backup, plus generation and consumption metering

Best for: Plants that must report faults to a control room and curtail output on network instruction.

Key specifications

Communications
Optical fibre cable (OFC)
Control
Remote monitoring and output curtailment
Metering
Generation and consumption

Packaged Solutions

Kiosk Substations

Fully integrated, transportable HV/LV turnkey substations delivered as a single factory-tested package.

  • Complete HV switchgear, transformer and LV distribution in one enclosure
  • Factory assembled and tested to cut on-site commissioning time
  • Transportable design suited to staged and remote deployments

Best for: Brownfield sites, commercial subdivisions and remote operations where on-site civil works must be minimised.

Key specifications

Configuration
Turnkey HV/LV package
Delivery
Transportable, single-lift
Testing
Full factory acceptance testing

Distribution Transformers

Fin Wall Transformers

Hermetically sealed transformers with integrated folded fin walls, removing the need for a nitrogen blanket.

  • Hermetically sealed tank with integrated folded fins for passive cooling
  • Zero nitrogen blanket required, eliminating cable box maintenance
  • Scalable across the distribution range up to 36 kV

Best for: Utility and industrial distribution networks where lifetime maintenance cost is the deciding factor.

Key specifications

Voltage
Up to 36 kV
Sealing
Hermetically sealed
Maintenance
No nitrogen blanket, no cable box servicing

Distribution Transformers

Dry Type Transformers

Moisture-proof, self-extinguishing and maintenance-free transformers built for occupied buildings.

  • No insulating oil, removing spill containment and fire load concerns
  • Self-extinguishing construction for maximum indoor fire safety
  • Maintenance-free operation across the service life

Best for: Indoor substations, high-rise buildings, data centres and sensitive commercial environments.

Key specifications

Cooling
Air cooled, oil free
Fire behaviour
Self-extinguishing
Ingress
Moisture-proof construction

Fire-Rated Solutions

FM Fire Mitigation Transformers

Superior fire protection design that reduces project footprint and removes structural blast walls.

  • Fire mitigation design allowing reduced separation distances
  • Eliminates the need for expensive structural blast walls
  • Recovers usable site area on constrained developments

Best for: Dense urban developments and constrained sites where every square metre carries cost.

Key specifications

Design intent
Fire mitigation rated
Site impact
Reduced footprint and separation
Civil works
No blast wall required

Distribution Transformers

Standard Substation Transformers

Heavy-duty, cost-competitive units built to AS 60076 for demanding industrial duty.

  • Built to AS 60076 standards
  • Heavy-duty construction for continuous industrial loading
  • Cost-competitive for volume and repeat deployments

Best for: Heavy industrial plants and mining operations needing proven, robust, compliant units.

Key specifications

Standard
AS 60076
Duty
Heavy industrial and mining
Construction
Ruggedised for harsh environments